Parameter |
Value |
Comments |
|
|
Device |
EXT 2 |
|
MP 5200.1 |
2 |
|
MP 5201.1 |
3 |
|
MP 5020.1 |
104 |
7Bits, Even, 2 stopbits, Use DC Code (XOn/Xoff) |
MP 5030.1 |
0 |
Blockwise Disabled. (1=Blockwise Enabled see below) |
|
|
in the DNC software Set Baud rate 2400. 7 DataBits. Even. 2 StopBits |
|
|
If Blockwise is disabled then select XOn/XOff flow control in the DNC software. The DNC Software should also insert STX and ETX codes into the transmit data - For example with easyDnc this is acheived in the DNC Setup window by selecting 'Advanced' and select these options from the drop-lists.
ASCII Start Code = STX (02)
ASCII End Code = ETX (03)
|
|
1 |
This control supports the Heidenhain blockwise communications protocol for reliable file transfer and drip feeding of large programs that exceed the memory of the control. Enable Blockwise by setting MP5030.1=1 and use a DNC Program that supports Blockwise such as RemoDNC.
See additional information about Blockwise setup of RemoDNC |
Cable shown here works with xOn/xOff (DC1/DC3) flow control and RTS/CTS (Hardware flow control so should work in most cases.
The cable shown here is the minimum required for software flow control and the heidhain blockwise protocol. Other cable such as this one |
RS232 Cable.
9pin computer to 25pin CNC
|