CNC / DNC Settings for Heidenhain TNC360
Parameter |
Value |
Comments |
|
|
Baud Rate |
|
TNC External Interface is capable of speeds between 110 and 38400. For non-blockwise transfers in to CNC memory we would suggest using 4800 or lower. But if you need to drip feed large complex programs then a higher speed will almost certainly be required and you should enable the Blockwise Protocol mentioned below. |
Device |
EXT |
RS232 Interface |
5010.0 |
515 |
|
5010.1 |
17736 |
|
5010.2 |
16712 |
|
5010.3 |
279 |
|
5010.4 |
5382 |
|
5010.5 |
4 |
|
5020 |
104 |
7bits. Even parity. 2 Stop Bits. use DC3 (xOnXoff)
|
5030 |
1 |
Blockwise Protocol Enabled (0 = Disabled)
|
|
|
The Heidenhain TNC 360 can be configured to use the Heidenhain Blockwise Protocol for high speed reliable drip feeding of programs that exceed the memory capacity of the machine. Blockwise Protocol is Enabled/Disabled via parameter 5030.
Use a DNC program capable of communicating using Heidenhain Blockwise.
See this page for setting up RemoDNC to drip feed large programs using Heidenhain Blockwise Protocol |
|
RS232 Cable.
9pin computer to 25pin CNC
|
|
|
|
|
|
DNC Software for Windows 8, Windows 7, Vista and Windows XP. 32 and 64bit versions
for
Acramatic, Fanuc, Okuma, Sinumerik and many other ISO - ASCII CNC Controls.
Single or Multi-Tasking to Communicate with one or more than one control at the same time. |
|
|
|
MiniMRP is an easy to use Inventory Manager with Multi-Level BOM Manager and other 'MRP'
features usually only available in larger MRP/ERP packages.
Inventory, Single and Multi-Level BOM for less that $200 |